{"id":4907,"date":"2024-02-27T09:37:47","date_gmt":"2024-02-27T07:37:47","guid":{"rendered":"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/"},"modified":"2024-02-27T16:12:05","modified_gmt":"2024-02-27T14:12:05","slug":"offline-insulation-monitoring-device-for-industrial-use","status":"publish","type":"post","link":"https:\/\/www.trafox.fi\/de\/offline-insulation-monitoring-device-for-industrial-use\/","title":{"rendered":"Offline Insulation Monitoring device for industrial use"},"content":{"rendered":"<table style=\"border-collapse: collapse; width: 77.2634%; height: 460px;\">\n<tbody>\n<tr style=\"height: 324px;\">\n<td style=\"height: 300px; text-align: left; vertical-align: middle; width: 250px;\"><a href=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4430 size-medium\" src=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-277x300.png\" alt=\"\" width=\"277\" height=\"300\" srcset=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-277x300.png 277w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-945x1024.png 945w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-768x833.png 768w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-1417x1536.png 1417w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-1889x2048.png 1889w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-129x140.png 129w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-300x325.png 300w\" sizes=\"auto, (max-width: 277px) 100vw, 277px\" \/><\/a><\/td>\n<td style=\"height: 300px; text-align: left; vertical-align: middle; width: 250px;\"><a href=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-4871\" src=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1-300x233.png\" alt=\"\" width=\"300\" height=\"233\" srcset=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1-300x233.png 300w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1-1024x796.png 1024w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1-768x597.png 768w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1-1536x1194.png 1536w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1-2048x1592.png 2048w, https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/IM01-3D-1-140x109.png 140w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left; vertical-align: top; width: 47.7002%;\"><strong>IM-04.INDD<\/strong><br \/>\nup to 3 x 173\/300 VAC<\/td>\n<td style=\"text-align: left; vertical-align: top; width: 45.1448%;\"><strong>IM-01.INDD<\/strong><br \/>\nup to 3 x 400\/690 VAC<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left; vertical-align: top; width: 47.7002%;\"><strong>IM-04.INDD.10 + HVC-10<\/strong><br \/>\nup to 3 x 400\/690 VAC<\/td>\n<td style=\"text-align: left; vertical-align: top; width: 45.1448%;\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Principle of operation<\/strong><\/p>\n<p>The system is equipped with a disconnection contactor which is controlled by the IMD. When the system is started, the disconnection contactor is open, disconnecting the load network from the supply network. At the same time, the NC auxiliary contacts of the disconnection contactor connects the supply network to the measurement input connectors of the IMD. When the load network is supposed to be connected to the supply network, a command is sent to the IMD through the Modbus RTU interface. After receiving the connection command, the IMD disables insulation monitoring and powers the disconnection contactor, which connects the load network to the supply network and disconnects the measurement inputs from the load network. Disconnecting the load network from the supply network works the same way in the opposite manner.<\/p>\n<p>The disconnection contactor must have 4 NO contacts and 2 NC auxiliary contacts. A suitable type is, for example, ABB AF116B-40-22-13 for up to 55 kW loads or some higher power version of the similar type. The voltage rating of the auxiliary contacts must be suitable for the network voltage.<\/p>\n<p>Download the Product Sheet from here: <a href=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2024\/02\/Superintend-Offline-IMD-rev2.pdf\">Trafox Superintend Offline IMD, EN (pdf)<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>IM-04.INDD up to 3 x 173\/300 VAC IM-01.INDD up to 3 x 400\/690 VAC IM-04.INDD.10 + HVC-10 up to 3 x 400\/690 VAC &nbsp; Principle of operation The system is equipped with a disconnection contactor which is controlled by the IMD. When the system is started, the disconnection contactor is open, disconnecting the load network [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":true,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7],"tags":[],"class_list":["post-4907","post","type-post","status-publish","format-standard","hentry","category-yleinen-de"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.10 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Offline Insulation Monitoring device for industrial use - Trafox<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Offline Insulation Monitoring device for industrial use - Trafox\" \/>\n<meta property=\"og:description\" content=\"IM-04.INDD up to 3 x 173\/300 VAC IM-01.INDD up to 3 x 400\/690 VAC IM-04.INDD.10 + HVC-10 up to 3 x 400\/690 VAC &nbsp; Principle of operation The system is equipped with a disconnection contactor which is controlled by the IMD. When the system is started, the disconnection contactor is open, disconnecting the load network [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/\" \/>\n<meta property=\"og:site_name\" content=\"Trafox\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-27T07:37:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-27T14:12:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-277x300.png\" \/>\n<meta name=\"author\" content=\"trafox\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"trafox\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/\",\"url\":\"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/\",\"name\":\"Offline Insulation Monitoring device for industrial use - Trafox\",\"isPartOf\":{\"@id\":\"https:\/\/www.trafox.fi\/#website\"},\"datePublished\":\"2024-02-27T07:37:47+00:00\",\"dateModified\":\"2024-02-27T14:12:05+00:00\",\"author\":{\"@id\":\"https:\/\/www.trafox.fi\/#\/schema\/person\/41d1b473d784834f044ec97cdb5acbfa\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.trafox.fi\/de\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Offline Insulation Monitoring device for industrial use\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.trafox.fi\/#website\",\"url\":\"https:\/\/www.trafox.fi\/\",\"name\":\"Trafox\",\"description\":\"Maailmanluokan laatua. Suomalaisella asenteella.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.trafox.fi\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.trafox.fi\/#\/schema\/person\/41d1b473d784834f044ec97cdb5acbfa\",\"name\":\"trafox\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/www.trafox.fi\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/6985b7594457bda6809fa1eb25588de86d6b42546c358d34c8d8767a372d4075?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/6985b7594457bda6809fa1eb25588de86d6b42546c358d34c8d8767a372d4075?s=96&d=mm&r=g\",\"caption\":\"trafox\"},\"url\":\"https:\/\/www.trafox.fi\/de\/author\/trafox\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Offline Insulation Monitoring device for industrial use - Trafox","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/","og_locale":"de_DE","og_type":"article","og_title":"Offline Insulation Monitoring device for industrial use - Trafox","og_description":"IM-04.INDD up to 3 x 173\/300 VAC IM-01.INDD up to 3 x 400\/690 VAC IM-04.INDD.10 + HVC-10 up to 3 x 400\/690 VAC &nbsp; Principle of operation The system is equipped with a disconnection contactor which is controlled by the IMD. When the system is started, the disconnection contactor is open, disconnecting the load network [&hellip;]","og_url":"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/","og_site_name":"Trafox","article_published_time":"2024-02-27T07:37:47+00:00","article_modified_time":"2024-02-27T14:12:05+00:00","og_image":[{"url":"https:\/\/www.trafox.fi\/wp-content\/uploads\/2023\/02\/IM-04_HV-e1709031915161-277x300.png"}],"author":"trafox","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"trafox","Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/","url":"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/","name":"Offline Insulation Monitoring device for industrial use - Trafox","isPartOf":{"@id":"https:\/\/www.trafox.fi\/#website"},"datePublished":"2024-02-27T07:37:47+00:00","dateModified":"2024-02-27T14:12:05+00:00","author":{"@id":"https:\/\/www.trafox.fi\/#\/schema\/person\/41d1b473d784834f044ec97cdb5acbfa"},"breadcrumb":{"@id":"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.trafox.fi\/offline-insulation-monitoring-device-for-industrial-use\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.trafox.fi\/de\/"},{"@type":"ListItem","position":2,"name":"Offline Insulation Monitoring device for industrial use"}]},{"@type":"WebSite","@id":"https:\/\/www.trafox.fi\/#website","url":"https:\/\/www.trafox.fi\/","name":"Trafox","description":"Maailmanluokan laatua. Suomalaisella asenteella.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.trafox.fi\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"de"},{"@type":"Person","@id":"https:\/\/www.trafox.fi\/#\/schema\/person\/41d1b473d784834f044ec97cdb5acbfa","name":"trafox","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.trafox.fi\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/6985b7594457bda6809fa1eb25588de86d6b42546c358d34c8d8767a372d4075?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6985b7594457bda6809fa1eb25588de86d6b42546c358d34c8d8767a372d4075?s=96&d=mm&r=g","caption":"trafox"},"url":"https:\/\/www.trafox.fi\/de\/author\/trafox\/"}]}},"_links":{"self":[{"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/posts\/4907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/comments?post=4907"}],"version-history":[{"count":4,"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/posts\/4907\/revisions"}],"predecessor-version":[{"id":4923,"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/posts\/4907\/revisions\/4923"}],"wp:attachment":[{"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/media?parent=4907"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/categories?post=4907"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.trafox.fi\/de\/wp-json\/wp\/v2\/tags?post=4907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}