MONITORING UNITS
AND SUPPLY VOLTAGES

USA
Type Supply Voltage Listing
VR-14US/1
VR-14US/10UL
VR-14US/100UL
110-120 VAC, 60 Hz
110-120 VAC, 60 Hz
110-120 VAC, 60 Hz
-
UL
UL
VR-14US/1DC
VR-14US/10ULDC
VR-14US/100ULDC
24 VDC
24 VDC
24 VDC
-
UL
UL
VRE-10US 24 VAC and 24 VDC ETL
VRE-11AUS
VRE-11A/100US
VRE-11PUS
110-120 VAC, 60 Hz
110-120 VAC, 60 Hz
110-120 VAC, 60 Hz
ETL
ETL
-
VRE-80US
VRE-80MUS
VRE-80PUS
110-120 VAC, 60 Hz
110-120 VAC, 60 Hz
110-120 VAC, 60 Hz
ETL
ETL
-

Other countries
languages: English (E), Finnish (F),
German (D), Swedish (S)
Type Supply Voltage Listing
VR-14/1
VR-14/10
VR-14/100
VR-15/1
VR-15/10
VR-15/100
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
CE
CE
CE
CE
CE
CE
VRE-10E 24 VAC and 24 VDC CE
VRE-11A
VRE-11A/100
VRE-11P
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
CE
CE
CE
VRE-80M
VRE-80P
220-240 VAC, 50 Hz
220-240 VAC, 50 Hz
CE
CE

MEASURING RANGE, ALARM SETTING, DISPLAY AND MEASURING DISTANCE

Type Mon.
Point
Measuring
Range
Alarm Setting Current Display Measuring
Distance (max)
VR-14/1
VR-15/1
1 1 mA-
10 A
5 mA, 10 mA,
30 mA, 100 mA,
300 mA, 1 A
Digital Built-in
transformer
D=5/8" (16 mm)
VR-14/10
VR-15/10
1 10 mA-
10 A
30 mA, 10 mA,
300 mA, 1 A,
3 A, 10 A
Digital 32 ft (10 m) with
Standard
Measuring Cable
VR-14/100
VR-15/100
1 100 mA-
100 A
300 mA, 1 A,
3 A, 10 A, 30 A,
100 A
Digital 32 ft (10 m) with
Standard
Measuring Cable
Remark: VR-14 models are with manual reset and VR-15 models are with automatic reset.
VRE-10
1 5 mA-
9.99 A
Range / Step
10 mA-
100 mA
step 10 mA
100 mA-1.0 A
step 25 mA
1 A-9.5 A
step 0.25 A
Digital resolution
I < 1 A
1 mA
I > 1 A
10 mA
32 ft (10 m)
with standard
measuring
cable

300 ft (100 m)
with
instrumentation
cable

VRE-11A
1 1 mA-
9.99 A
Range / Step
10 mA-
100 mA
step 10 mA

100 mA-1 A
step 25 mA

1 A-9.75 A
step 0.25 A

Digital resolution
I < 1 A
1 mA

I > 1 A
10 mA

32 ft (10 m)
with standard
measuring
cable,

300 ft (100 m)
with
instrumentation
cable

VRE-11A/100
1 10 mA-
99.9 A
Range / Step
10 mA-
100 mA
step 10 mA
100 mA-1 A
step 25 mA
1 A-10 A /
0.25 A
10 A-97.5 A /
2.5 A
Digital resolution
I < 10 A
10 mA
I > 10 A
100 mA
32 ft (10 m)
with standard
measuring
cable,

300 ft (100 m)
with
instrumentation
cable

VRE-11P
VRE-11P/100

Portable models
1 Similar technical data as models
VRE-11A and VRE-11A/100
32 ft (10 m)
with standard
measuring
cable,

300 ft (100 m)
with
instrumentation
cable

VRE-80
8 1 mA-
12 A
5, 6, 7, 8, 9, 10, 12,
15, 20, 30, 40...
10.000 mA
grows with
locarithmic scale
Digital resolution
I < 1 A
1 mA

I > 1 A
10 mA

32 ft (10 m)
with standard
measuring
cable,
300 ft (100 m)
with
instrumentation
cable
VRE-80M

with Modbus protocol
8-
256
1 mA-
12 A
5, 6, 7, 8, 9, 10, 12,
15, 20, 30, 40...
10.000 mA
grows with
locarithmic scale

with Master
program:
5 mA to 10 A
continuous

Digital resolution
I < 1 A
1 mA

I > 1 A
10 mA

PC with Modbus
Master program
Internet with PC

Same as
above,

Modbus
Local Area
Network:
max. distance,
with cable
4.000 ft (1.200 m)
with optical fibre
cable more

VRE-80P
VRE-80MP

Portable models
8-
256
Similar technical data as models
VRE-80 and VRE-80M
Same as
above,

Modbus
Local Area
Network:
max.
distance
4.000 ft
(1.200 m)